A safety switch cuts the power in milliseconds when current leaks to earth. If your board does not have one on every circuit, or one keeps tripping, this is the work to do first.
Tell us the job — we come back with a fixed price.
They look similar and do different jobs. A circuit breaker protects the cable from overload and short circuit. A safety switch (RCD) protects people from electric shock and is also the device that catches leaking appliances and damaged wiring.
A board can look modern and still have no safety-switch protection on lighting or power circuits — which is exactly the installation that gives no warning before it hurts someone.
We test the circuit with an insulation resistance meter, identify whether it is the appliance, the cable or moisture in a fitting, and repair that — the device is usually the messenger, not the fault.
We fit safety switches to the circuits that need protection, check they operate within the required trip time using a current-injection tester, and label them. The push-button test on the device is a check that it operates mechanically; it does not prove it will trip at the right current and time — only a test instrument does that.
Yes. They are mechanical devices with electronics inside and they do wear out. Manufacturers specify regular push-button testing by the occupant and periodic instrument testing, which is why a tripping or dead device is replaced rather than argued with.
Almost always water getting into an outdoor light, power point or pump circuit. The RCD is working correctly — the fix is finding and sealing the ingress, not replacing the switch.
Current standards require protection on the circuits they cover, and older installations were built before that. We tell you which circuits are protected and which are not, so you can decide what to fix now.
AIRSOLAR PTY LTD trading as AirSolar Power, Queensland Electrical Contractor Licence 1513126 (unrestricted).